- Abstract:
- Chemical actinometer solution (KI/KIO3) was sealed and utilized to measure the irradiance of a low pressure UV lamp in water. The UV output of a lamp could be calculated using the diffuse radiation model based on the measured irradiance data. The international ultraviolet association (IU-VA) recommends the method based on the Keitz equation to measure the UV output of a lamp in air, which is an application of the diffuse radiation model when the absorbance coefficient of the media is zero. This work proposed to expand the application of the IUVA method in water. The influences of the concentration of chemical actinometer solution and the mixing of the solution inside the container were researched. Reflections from the quartz window and the surface of the solution, as well as energy loss inside quartz were calculated. The potential errors on the energy losses were removed. The results indicated good measurement accuracy of the proposed method. The relative difference between two measurements of an 8 W low pressure UV lamp in water with different UV absorbance coefficients was 1.73%.
References:
[1]张光辉,顾平,于丹丹. 紫外线消毒器水力特性的研究[J]. 水处理技术,2008,34(2):16-20.
Zhang Guanghui,Gu Ping,Yu Dandan. Hydraulic characteristics of UV disinfector [J]. Technology of Water Treatment,2008,34(2):16-20(in Chinese).
[2]Wols B A,Shao L,Uijttewaal W S J,et al. Evaluation of experimental techniques to validate numerical computations of the hydraulics inside a UV benchscale reactor[J]. Chem Eng Sci,2010,65(15):4491-4502.
[3]李继,张艳,董文艺. 基于CFD的两种紫外消毒模型的比较研究[J]. 环境工程学报,2012,6(1):125-129.
Li Ji,Zhang Yan,Dong Wenyi. Comparison of two different UV disinfection models by CFD[J]. Chinese Journal of Environmental Engineering,2012,6(1):125-129(in Chinese).
[4]Sultan T. Numerical study of the effects of lamp configuration and reactor wall roughness in an open channel water disinfection UV reactor[J]. Chemosphere,2016,155:170-179.
[5]张连峰,张金松,刘文君,等. 紫外线在消毒与环境净化应用中的辐射量的测量和计算[J]. 中国给水排水,2017,33(20):41-45.
Zhang Lianfeng,Zhang Jinsong,Liu Wenjun,et al. Measurement and calculation of ultraviolet radiation in disinfection and environmental purification[J]. China Water & Wastewater,2017,33(20):41-45(in Chinese).
[6]Lawal O,Dussert B,Howarth C,et al. Proposed method for measurement of the output of monochromatic(254 nm) low pressure UV lamps[J]. IUVA News,2008,10(1):14-17.
[7]Masschelein W J,Rice R G. Ultraviolet Light in Water and Wastewater Sanitation[M]. Boca Raton:Crc Press,2002.
[8]Bolton J R,Stefan M I,Shaw P,et al. Determination of the quantum yields of the potassium ferrioxalate and potassium iodideiodate actinometers and a method for the calibration of radiometer detectors[J]. J Photochem Photobiol A: Chem,2011,222(1):166-169.
[9]Qiang Z,Li W,Li M,et al. Inspection of feasible calibration conditions for UV radiometer detectors with the KI/KIO3 actinometer[J]. Photochem Photobiol,2015,91(1):68-73.
[10]Rahn R O,Bolton J,Stefan M I. The iodide/iodate actinometer in UV disinfection: Determination of the fluence rate distribution in UV reactors[J]. Photochem Photobiol,2006,82(2):611-615.
[11]Rahn R O. Fluence measurements employing iodide/iodate chemical actinometry as applied to upperroom germicidal radiation[J]. Photochem Photobiol,2013,89(4):816-818.
[12]Bolton J R. Calculation of ultraviolet fluence rate distributions in an annular reactor:significance of refraction and reflection[J]. Water Res,2000,34(13):3315-3324.
[13]孙文俊,刘文君,胡田甜,等. 紫外线消毒系统中强度分布的理论计算与生物验证对比[J]. 环境科学学报,2008,28(3):563-567.
Sun Wenjun,Liu Wenjun,Hu Tiantian,et al. Comparison of theoretical computation and bioassays of UV intensity distribution in an ultraviolet disinfection reactor[J]. Acta Scientiae Circumstantiae,2008,28(3):563-567(in Chinese).
[14]李梦凯,强志民,史彦伟,等. 紫外消毒系统有效辐射剂量测试方法研究进展[J]. 环境科学学报,2012,32(3):513-520.
Li Mengkai,Qiang Zhimin,Shi Yanwei,et al. Research progress on the effective dose measurement methods for UV disinfection facilities[J]. Acta Scientiae Circumstantiae,2012,32(3):513-520(in Chinese).
[15]张光辉,顾平. 封闭式紫外线消毒器光强计算及分布规律研究[J]. 给水排水,2013,39(s1):88-93.
Zhang Guanghui,Gu Ping. Distribution and calculation of ultraviolet intensity in a closed channel ultraviolet disinfection reactor[J]. Water & Wastewater Engineering,2013,39(s1):88-93(in Chinese).
[16]Boyjoo Y,Sun H,Liu J,et al. A review on photocatalysis for air treatment:From catalyst development to reactor design[J]. Chem Eng J,2017,310:537-559.
[17]Rahn R O,Stefan M I,Bolton J R,et al. Quantum yield of the iodideiodate chemical actinometer:dependence on wavelength and concentrations[J]. Photochem Photobiol,2003,78(2):146-152.
[18]Goldstein S,Rabani J. The ferrioxalate and iodideiodate actinometer in the UV region[J]. J Photochem Photobiol A:Chem,2008,193(1):50-55.
[19]Muller A,Stahl M R,Greiner R,et al. Performance and dose validation of a coiled tube UVC reactor for inactivation of microorganisms in absorbing liquids[J]. J Food Eng,2014,138:45-52.
[20]Rahn R O. Potassium iodide as a chemical actinometer for 254 nm radiation:Use of iodate as an electron scavenger[J]. Photochem Photobiol,1997,66(6):450-455.
[21]Jin S,Mofidi A A,Linden K G. Polychromatic UV fluence measurement using chemical actinometry,biodosimetry,and mathematical techniques[J]. J Environ Eng,2006,132(8):831-841.
[22]Zhang L,Anderson W A. A finite model for the prediction of the UV radiation field around a linear lamp[J]. Chem Eng Sci,2010,65(5):1513-1521.
Memo
通信作者:张连峰E-mail:tyou6@hotmail.com
作者简介:
陈钰(1993- ),女,贵州贵阳人,硕士研究生,研究方向为紫外线在水净化领域的应用。
E-mail:goover-cy@163.com