ZHU Shi-hui,ZHANG Zhe,ZHAO Zhen-yi,et al.Influence of Top Ventilation Mode on Special Ventilation and Drainage System[J].China Water & Wastewater,2020,36(17 17):62-68.
Influence of Top Ventilation Mode on Special Ventilation and Drainage System
China Water & Wastewater[ISSN:1000-4062/CN:12-1073/TU]
volume:
第36卷
Number:
17 17
Page:
62-68
Column:
Date of publication:
2020-09-01
- Keywords:
- special ventilation and drainage system; top ventilation mode; drainage capacity; extended top ventilation; side wall ventilation; ventilation flow
- Abstract:
- On a full scale experimental tower with height of 122.9 m, special ventilation and drainage system with H pipe connected each floor with different ventilation modes (extended top ventilation or side wall ventilation) at the top of the drainage pipe was compared. The influence of the top ventilation modes on pressure and ventilation flow in the drainage system was explored, so as to study its effect on the drainage capacity of the special ventilation and drainage system. Compared with extended top ventilation, side wall ventilation led to a reduction of the minimum pressure (Psmin), ventilation flow (Q2) into the top of the special vertical vent and drainage capacity of the system.