- Keywords:
- container wharf; outdoor fire fighting system; fire hydrant; American standard; British standard
- Abstract:
- Based on the experience of design and construction of multiple overseas container wharfs, the fire fighting system design method of the container wharf outdoor storage yard adopting American standards or British standards was introduced, including fire hydrant flow rate for outdoor storage yards, values of fire hydrants outlet residual pressure and fire duration time, interval of fire hydrants, and plane layout of fire hydrants, etc. In addition, the selection principles of interface standard of fire hydrants and fire water gun parameters were also introduced, which could provide references to the design of fire protection system for outdoor storage yards of overseas container wharfs, as well as to the design of outdoor fire fighting systems of other engineerings.