SUN Jian-yu,LEI Ting,LIANG Peng,et al.Application and Optimization of Pulse Aeration in Large-scale Membrane Bioreactor[J].China Water & Wastewater,2021,37(9 9):100-104.
Application and Optimization of Pulse Aeration in Large-scale Membrane Bioreactor
China Water & Wastewater[ISSN:1000-4062/CN:12-1073/TU]
volume:
第37卷
Number:
9 9
Page:
100-104
Column:
Date of publication:
2021-05-01
- Keywords:
- membrane bioreactor; pulse aeration; membrane fouling; optimization
- Abstract:
- Application and optimization of pulse aeration in membrane tanks were carried out in a large-scale membrane bioreactor (MBR) plant for municipal wastewater treatment, which aimed to determine the optimal aeration parameters for the project and to reveal the variation rule of the mixed liquid characteristics and membrane fouling under different aeration intensities. The specific membrane flux increased first and then decreased in the membrane tanks as the total aeration flow rate increased from 13 000 m3/h to 17 000 m3/h. The increase of aeration flow rate led to smaller particle size of the sludge in mixed liquor, lower organic concentration in loosely bound extracellular polymeric substances (LB-EPS) on sludge and higher organic concentration in supernatant, resulted in higher membrane fouling potential of supernatant. By comprehensive comparison, the optimal aeration rate of the MBR membrane tank was medium aeration rate (15 000 m3/h). Under the optimal condition, the average specific flux of the modules in the membrane tank reached 0.95 L/(m2·h·kPa).
Last Update:
2021-05-01