WANGZi-qi,XUQiang,ZHENGCheng-zhi,et al.Influences of Data Acquisition Settings on the DMA Flow Patterns[J].China Water & Wastewater,2022,38(8):20-24.
Influences of Data Acquisition Settings on the DMA Flow Patterns
China Water & Wastewater[ISSN:1000-4062/CN:12-1073/TU]
volume:
第38卷
Number:
第8期
Page:
20-24
Column:
Date of publication:
2022-04-17
- Keywords:
- district metered area; data acquisition period; data precision; flow pattern; minimum night flow
- Abstract:
- Water consumption data monitored by smart water meters provide a crucial foundation for determination of water consumption pattern and water loss analysis in water distribution systems. However, the analysis results could be critically influenced by data precision and acquisition period. Based on the water flow data from water meters at ten district metered area (DMA) entrances, this study analyzed the influences of acquisition period and data precision on the calculation of minimum night flow (MNF) and the analysis of DMA flow pattern. The results indicated that the increase in acquisition period would raise the MNF calculation results and deteriorate the fineness of water consumption pattern. Water consumption would follow a pattern of stages or even two lines with the reduction of data precision, which could not reflect the real water consumption pattern. The investigation illustrates the relationship between the acquisition period and data precision of the water meter, which needs to match with each other during the parameter setting.
Last Update:
2022-04-17