采用共沉淀法制备了磁性锆铁改性沸石,在研究其对疏浚余水中磷酸盐吸附特性的基础上,采用X射线衍射仪(XRD)表征其结构,探讨吸附磷的特性。结果表明,Langmuir等温吸附模型、准二级动力学模型和颗粒内扩散模型均可以较好地描述磁性锆铁改性沸石对疏浚余水中磷酸盐的吸附特征。当吸附剂投加量为18 mg/L、pH值为7时,疏浚余水中磷酸盐的饱和吸附量为11.4 mg/g(以磷计);当pH值为5~7时,磁性锆铁改性沸石对磷酸盐的吸附效果较好,偏碱性条件下吸附量明显下降;当水温在10~30 ℃时,对磷酸盐的吸附效果随温度的升高而增加;磁性锆铁改性沸石吸附水中磷酸盐的过程属于化学吸附。
- Abstract:
-
Zeolite modified with magnetic zirconium/iron was prepared by coprecipitation method. Based on exploring its adsorption characteristics of phosphate in residual dredging water, the phosphate adsorption characteristics were determined through characterization of its structure by XRD. The adsorption characteristics of the phosphate in the residual dredging water by the zeolite modified with magnetic zirconium/iron could be described by Langmuir isothermal adsorption model, quasi- secondary kinetic model and particle internal diffusion model. When the adsorbent dosage was 18 mg/L and the pH was 7, the maximum adsorption capacity of phosphate in the residual dredging water was 11.4 mg/g (calculated as phosphorus). When the pH was between 5 and 7, the adsorption efficiency of the zeolite modified with magnetic zironium/iron on phosphate was better, and the adsorption amount decreased obviously under alkaline condition. When the temperature was between 10 ℃ and 30 ℃, the adsorption efficiency of phosphate increased with the increase of temperature. The adsorption of phosphate in water by the zeolite modified with magnetic zirconium/iron belonged to chemical adsorption.
相似文献/References:
[1]孙永利,张维,郑兴灿,等.城镇居民人均日生活污水污染物产生量测算之产污规律[J].中国给水排水,2020,36(6):1.
[2]范荣桂,刘娜,尹利鹏,等.污泥厌氧催化快速发酵产VFAs的试验研究[J].中国给水排水,2020,36(11):69.
[3]镇祥华,余琴芳,万年红,等.污水处理厂二级出水深床滤池超深度脱氮研究[J].中国给水排水,2020,36(11):91.
[4]赵美玲,朱涛,冯江,等.水力模型在合流制调蓄池进水管改造中的应用[J].中国给水排水,2020,36(7):114.
[5]朱一文,王文亮.基于水文方法的暴雨调节塘规模计算[J].中国给水排水,2020,36(7):118.
[6]李骏飞,李欢,杨磊三.粤港澳大湾区创新治水模式分享[J].中国给水排水,2020,36(8):1.
[7]李激,王燕,熊红松,等.城镇污水处理厂消毒设施运行调研与优化策略[J].中国给水排水,2020,36(8):7.
[8]赵锡锋,李兴强,李军.好氧颗粒污泥技术中试研究及应用进展[J].中国给水排水,2020,36(8):30.
[9]王建西.PTA2O工艺用于养猪废水处理及其Anammox现象分析[J].中国给水排水,2020,36(8):56.
[10]高海英,邓磊,侯晓庆,等.MBR工艺在西安经开草滩污水处理厂中的应用[J].中国给水排水,2020,36(8):63.
[11]莫俊锋,王文亮,白献宇,等.基于设计暴雨法的CSO调蓄池池容计算方法探讨[J].中国给水排水,2020,36(8):77.
[12]郭健.纳入大直径热力管的综合管廊设计研究[J].中国给水排水,2020,36(8):82.
[13]蒙政成,冼萍,黄付平,等.NCMBR工艺在工业园区污水处理工程中的应用[J].中国给水排水,2020,36(8):88.