城市生活垃圾综合处理厂渗滤液全量化处理工程设计
- Title:
- Project Design of Total Quantitative Treatment of Leachate of Urban Municipal Waste Comprehensive Treatment Plant
- 关键词:
- font-size: 10pt; ">生活垃圾综合处理厂; 垃圾渗滤液; 全量化处理; MBR; DTRO
- Keywords:
-
urban municipal waste comprehensive treatment plant
; landfill leachate; total font-size: 10pt; ">quantitative treatment; MBR; DTRO
- 摘要:
-
针对北方某城市生活垃圾综合处理厂渗滤液的水质特点,采用中温厌氧—MBR(含一级A/O硝化反硝化)—碟管式反渗透(DTRO)工艺进行处理, DTRO浓缩液采用碟管式纳滤(DTNF)+高压级碟管式反渗透(HPRO)+机械式蒸汽再压缩(MVR)工艺进行处理,实现渗滤液的全量化处理。该工程设计处理规模为150 m3/d,介绍了该工程的工艺流程、处理系统的组成及主要工艺单元设计参数。工程运行结果表明,该工艺运行稳定、处理效果好,出水水质达到《城市污水再生利用 城市杂用水水质》(GB/T 18920—2002)中城市绿化和车辆冲洗标准和《城市污水再生利用 工业用水水质》(GB/T 19923—2005)中锅炉补给水和工艺与产品用水标准要求。
- Abstract:
-
According to the water quality characteristics of leachate from a municipal waste comprehensive treatment plant in northern China, a combination process of medium temperature anaerobic-MBR (including first-stage A/O nitrification and denitrification)-disc-tube reverse osmosis (DTRO) process was adopted to treat the leachate. The concentrate of DTRO was treated by combination process of disc-tube nanofiltration (DTNF)+high-pressure disc-tube reverse osmosis (HPRO)+mechanical vapor recompression (MVR). This realized the total quantitative treatment of leachate. The design treatment capacity of the process was 150 m 3 /d. The process flow, the composition of the process and the design parameters of the main treatment units were introduced. The results of project operation showed that the process ran steadily and had a good treatment performance. The effluent quality reached the standard of urban greening and vehicle flushing in The Reuse of Urban Recycling Water—Water Quality Standard for Urban Miscellaneous Water Consumption (GB/T 18920-2002) and the boiler replenishment water and process and product water in The Reuse of Urban Recycling Water—Water Quality Standard for Industrial Uses (GB/T 19923-2005).
相似文献/References:
[1]孙永利,张维,郑兴灿,等.城镇居民人均日生活污水污染物产生量测算之产污规律[J].中国给水排水,2020,36(6):1.
[2]范荣桂,刘娜,尹利鹏,等.污泥厌氧催化快速发酵产VFAs的试验研究[J].中国给水排水,2020,36(11):69.
[3]镇祥华,余琴芳,万年红,等.污水处理厂二级出水深床滤池超深度脱氮研究[J].中国给水排水,2020,36(11):91.
[4]赵美玲,朱涛,冯江,等.水力模型在合流制调蓄池进水管改造中的应用[J].中国给水排水,2020,36(7):114.
[5]朱一文,王文亮.基于水文方法的暴雨调节塘规模计算[J].中国给水排水,2020,36(7):118.
[6]李骏飞,李欢,杨磊三.粤港澳大湾区创新治水模式分享[J].中国给水排水,2020,36(8):1.
[7]李激,王燕,熊红松,等.城镇污水处理厂消毒设施运行调研与优化策略[J].中国给水排水,2020,36(8):7.
[8]赵锡锋,李兴强,李军.好氧颗粒污泥技术中试研究及应用进展[J].中国给水排水,2020,36(8):30.
[9]王建西.PTA2O工艺用于养猪废水处理及其Anammox现象分析[J].中国给水排水,2020,36(8):56.
[10]高海英,邓磊,侯晓庆,等.MBR工艺在西安经开草滩污水处理厂中的应用[J].中国给水排水,2020,36(8):63.
[11]莫俊锋,王文亮,白献宇,等.基于设计暴雨法的CSO调蓄池池容计算方法探讨[J].中国给水排水,2020,36(8):77.
[12]郭健.纳入大直径热力管的综合管廊设计研究[J].中国给水排水,2020,36(8):82.
[13]蒙政成,冼萍,黄付平,等.NCMBR工艺在工业园区污水处理工程中的应用[J].中国给水排水,2020,36(8):88.