构建了以水量水质监测和管道检测为基础、污水排水系统模型为支撑的城镇污水处理提质增效“十步法”研究总体框架。开展了某试点城市的案例研究,确定了2.6 km2的试点区域,并选择该区域最下游的管网出口节点作为提质增效成效的关键目标节点。基于建立的污水排水系统模拟模型,开展了7种排水管网整治方案情景的水量水质模拟。结果分析表明,在对区域内关键管网缺陷和排口修复改造的情景下,近期关键节点BOD5浓度可从现状63.57 mg/L提升至大于100 mg/L的目标值。
- Abstract:
-
A 10- step research framework for improving municipal wastewater treatment quality and efficiency based on water quantity and quality monitoring and pipeline detection was established and supported by a sewage drainage system model. A pilot area of 2.6 km2 in a pilot city was studied and the downstream outlet node of sewage pipe network was selected as the key target node for improving quality and efficiency. Based on the established sewage drainage system model, the simulation analysis of water quantity and quality was carried out for 7 drainage network renovation scenarios. The results showed that the BOD5 concentration of the critical node will increase from 63.57 mg/L to the target value of over 100 mg/L under the renovation scenarios of key pipe network defects and outlet reconstruction in the region in the near future.
相似文献/References:
[1]孙永利,张维,郑兴灿,等.城镇居民人均日生活污水污染物产生量测算之产污规律[J].中国给水排水,2020,36(6):1.
[2]范荣桂,刘娜,尹利鹏,等.污泥厌氧催化快速发酵产VFAs的试验研究[J].中国给水排水,2020,36(11):69.
[3]镇祥华,余琴芳,万年红,等.污水处理厂二级出水深床滤池超深度脱氮研究[J].中国给水排水,2020,36(11):91.
[4]赵美玲,朱涛,冯江,等.水力模型在合流制调蓄池进水管改造中的应用[J].中国给水排水,2020,36(7):114.
[5]朱一文,王文亮.基于水文方法的暴雨调节塘规模计算[J].中国给水排水,2020,36(7):118.
[6]李骏飞,李欢,杨磊三.粤港澳大湾区创新治水模式分享[J].中国给水排水,2020,36(8):1.
[7]李激,王燕,熊红松,等.城镇污水处理厂消毒设施运行调研与优化策略[J].中国给水排水,2020,36(8):7.
[8]赵锡锋,李兴强,李军.好氧颗粒污泥技术中试研究及应用进展[J].中国给水排水,2020,36(8):30.
[9]王建西.PTA2O工艺用于养猪废水处理及其Anammox现象分析[J].中国给水排水,2020,36(8):56.
[10]高海英,邓磊,侯晓庆,等.MBR工艺在西安经开草滩污水处理厂中的应用[J].中国给水排水,2020,36(8):63.
[11]莫俊锋,王文亮,白献宇,等.基于设计暴雨法的CSO调蓄池池容计算方法探讨[J].中国给水排水,2020,36(8):77.
[12]郭健.纳入大直径热力管的综合管廊设计研究[J].中国给水排水,2020,36(8):82.
[13]蒙政成,冼萍,黄付平,等.NCMBR工艺在工业园区污水处理工程中的应用[J].中国给水排水,2020,36(8):88.