以上海市宝山区张华浜东排水泵站和调蓄池的设计为例,针对泵站在进水条件较差、泵站位置狭小且不规则、雨水出水口位置受岸线码头阻挡等复杂地块条件下的不利因素进行了优化设计。提出了计算流体力学(CFD)进水流态模拟的优化分析、泵房与调蓄池合建式叠加布置的优化措施,并通过数模分析对穿越已建码头的出水口水流扩散参数进行了最低环境扰动的优化选择。
- Abstract:
-
Taking the design of Zhanghuabang East drainage pump station and storage tank in Baoshan District of Shanghai as an example, the design was optimized under complex land parcel conditions of poor inlet, narrow and irregular location, and the blocked stormwater outlet by waterfront wharf. The optimal analysis of inflow pattern simulation by computational fluid dynamics (CFD) and the optimal joint construction measures of pump house and the storage tank up and down were proposed. The optimal selection of the minimum environmental disturbance for the outlet flow diffusion parameters crossing the existing wharf was carried out by means of the numerical modeling analysis.
相似文献/References:
[1]孙永利,张维,郑兴灿,等.城镇居民人均日生活污水污染物产生量测算之产污规律[J].中国给水排水,2020,36(6):1.
[2]范荣桂,刘娜,尹利鹏,等.污泥厌氧催化快速发酵产VFAs的试验研究[J].中国给水排水,2020,36(11):69.
[3]镇祥华,余琴芳,万年红,等.污水处理厂二级出水深床滤池超深度脱氮研究[J].中国给水排水,2020,36(11):91.
[4]赵美玲,朱涛,冯江,等.水力模型在合流制调蓄池进水管改造中的应用[J].中国给水排水,2020,36(7):114.
[5]朱一文,王文亮.基于水文方法的暴雨调节塘规模计算[J].中国给水排水,2020,36(7):118.
[6]李骏飞,李欢,杨磊三.粤港澳大湾区创新治水模式分享[J].中国给水排水,2020,36(8):1.
[7]李激,王燕,熊红松,等.城镇污水处理厂消毒设施运行调研与优化策略[J].中国给水排水,2020,36(8):7.
[8]赵锡锋,李兴强,李军.好氧颗粒污泥技术中试研究及应用进展[J].中国给水排水,2020,36(8):30.
[9]王建西.PTA2O工艺用于养猪废水处理及其Anammox现象分析[J].中国给水排水,2020,36(8):56.
[10]高海英,邓磊,侯晓庆,等.MBR工艺在西安经开草滩污水处理厂中的应用[J].中国给水排水,2020,36(8):63.
[11]莫俊锋,王文亮,白献宇,等.基于设计暴雨法的CSO调蓄池池容计算方法探讨[J].中国给水排水,2020,36(8):77.
[12]郭健.纳入大直径热力管的综合管廊设计研究[J].中国给水排水,2020,36(8):82.
[13]蒙政成,冼萍,黄付平,等.NCMBR工艺在工业园区污水处理工程中的应用[J].中国给水排水,2020,36(8):88.