YIN Hai-long,LIAN Qing.Evaluation and Analysis of Wastewater Treatment Plant Operation in Residential and Industrial Hybrid Areas[J].China Water & Wastewater,2020,36(21):87-92.
生活和工业融合区污水处理厂运行评估分析
- Title:
- Evaluation and Analysis of Wastewater Treatment Plant Operation in Residential and Industrial Hybrid Areas
- 摘要:
- 以我国城镇化程度高和工业企业众多的江苏省部分区域为调查对象,选择6个地级市的62座城市污水处理厂,分析了污水厂进水水质和活性污泥系统的运行特征。受调查的污水处理厂进水COD、BOD5、SS、NH3-N、TN和TP的中位值分别为223、86.6、127、22.8、30.8和2.97 mg/L,表现为进水碳源不足和含有难降解COD。难降解工业废水的接入造成污水厂进水BOD5浓度降低最为明显和相应的SS/BOD5值偏高;进水BOD5浓度最低为38.5 mg/L,SS/BOD5值最高为5.8。活性污泥系统MLVSS与MLSS比值的中位值为0.52,最低为0.32,与污水营养物不足导致的活性污泥分解和工业废水中带入的无机细颗粒物在活性污泥中累积有关。为了满足城镇污水处理提质增效行动方案中对污水处理厂进水BOD5的要求(BOD5≥100 mg/L),除了加强管网排查和修复外,还应对工业企业接管进行评估和实施工业废水集中处理。
- Abstract:
- A survey was carried out in some areas of Jiangsu Province with a high degree of urbanization and a large number of industrial enterprises, in which 62 municipal wastewater treatment plants (WWTPs) in six cities were selected to analyze the influent quality and operational characteristics of activated sludge system. Monthly median concentrations of COD, BOD5, SS, NH3-N, TN and TP in influent of the WWTPs were 223 mg/L, 86.6 mg/L, 127 mg/L, 22.8 mg/L, 30.8 mg/L and 2.97 mg/L, respectively, indicating that the carbon source was insufficient and refractory COD was present. Refractory industrial wastewater entering into municipal WWTPs resulted in the most significant decrease of BOD5 concentrations in the influent and corresponding higher ratio of SS to BOD5. The lowest BOD5 concentration in the influent was 38.5 mg/L, and the highest ratio of SS to BOD5 was 5.8. The median and the lowest ratios of MLVSS to MLSS were 0.52 and 0.32, respectively, which was associated with activated sludge decomposition caused by insufficient nutrients supply and accumulation of inorganic fine sediments from industrial wastewater within the activated sludge. In order to meet the requirement of BOD5 concentration in the influent more than 100 mg/L in action plan for improving quality and efficiency of municipal wastewater treatment, attentions should be paid to assessment of enterprises with industrial wastewater entering into municipal sewers and implement of centralized industrial wastewater treatment, apart from strengthening sewer pipes inspection and repair.
相似文献/References:
[1]王 亮.马来西亚Pantai地埋式污水厂环网供配电结构设计[J].中国给水排水,2018,34(22):63.
WANG Liang.Power Supply and Distribution Structure Design of Ring Network for Pantai Underground Wastewater Treatment Plantin Malaysia[J].China Water & Wastewater,2018,34(21):63.
[2]侯晓庆,邓 磊,高海英,等.MBR工艺在神定河污水处理厂升级改造工程中的应用[J].中国给水排水,2018,34(22):66.
HOU Xiao-qing,DENG Lei,GAO Hai-ying,et al.Application of MBR Process in the Upgrading and Reconstruction Project of Shending River WastewaterTreatment Plant[J].China Water & Wastewater,2018,34(21):66.
[3]邱明海.北京市垡头污水处理厂改扩建工程设计技术方案[J].中国给水排水,2018,34(20):13.
QIU Ming hai.Reconstruction and Expansion Design Technical Plan of Beijing Fatou Wastewater Treatment Plant[J].China Water & Wastewater,2018,34(21):13.
[4]郝二成,郭毅,刘伟岩,等.基于数学模拟的污水厂运行分析——建模与体检[J].中国给水排水,2020,36(15):23.
HAO Er-cheng,GUO Yi,LIU Wei-yan,et al.Operation Analysis of Wastewater Treatment Plant Based on Mathematical Simulation: Modeling and Examination[J].China Water & Wastewater,2020,36(21):23.
[5]张月,王阳,张宏伟,等.阳泉市污水处理二期工程BARDENPHO工艺设计和运行[J].中国给水排水,2020,36(16):64.
ZHANG Yue,WANG Yang,ZHANG Hong-wei,et al.Design and Operation of BARDENPHO Process in Phase Ⅱ Project of Yangquan Wastewater Treatment Plant[J].China Water & Wastewater,2020,36(21):64.
[6]祝新军,蔡芝斌,姚斌,等.绍兴污水处理厂气浮设备的优化改造[J].中国给水排水,2020,36(16):101.
ZHU Xin-jun,CAI Zhi-bin,YAO Bin,et al.Optimization and Modification of Air Floatation Equipment in Shaoxing Wastewater Treatment Plant[J].China Water & Wastewater,2020,36(21):101.
[7]王文明,杨淇椋,蔡依廷,等.MSBR工艺在高排放标准污水处理厂的应用[J].中国给水排水,2020,36(16):111.
WANG Wen-ming,YANG Qi-liang,CAI Yi-ting,et al.Application of MSBR Process in Wastewater Treatment Plant with Stringent Discharge Standard[J].China Water & Wastewater,2020,36(21):111.
[8]郝二成,郭毅,刘伟岩,等.基于数学模拟的污水厂运行分析——控制与优化[J].中国给水排水,2020,36(17):23.
HAO Er-cheng,GUO Yi,LIU Wei-yan,et al.Operation Analysis of Wastewater Treatment Plant Based on Mathematical Simulation: Control and Optimization[J].China Water & Wastewater,2020,36(21):23.
[9]王阳,张月,王晓康,等.高排放标准下的改良AAO+深度处理工程案例[J].中国给水排水,2020,36(18):56.
WANG Yang,ZHANG Yue,WANG Xiao-kang,et al.Project Case of Modified AAO and Advanced Treatment Process under High Emission Standards[J].China Water & Wastewater,2020,36(21):56.
[10]郑枫,慕杨,孙逊.MBR工艺用于山东省某污水处理厂扩建工程[J].中国给水排水,2020,36(18):81.
ZHENG Feng,MU Yang,SUN Xun.MBR Process Used in Expansion Project of a Sewage Treatment Plant in Shandong Province[J].China Water & Wastewater,2020,36(21):81.