- 摘要:
- 经技术、经济比选五种常用的自动灭火系统后,长沙某综合管廊工程消防系统确定采用超细干粉自动灭火系统。采用体积法进行灭火设计计算,灭火浓度为0.15 kg/m3,每具装置的充装量为5 kg,电力舱和综合舱灭火装置布置间距分别为3.3 m和3.2 m。经检验,电力舱和综合舱自动灭火系统开口面积分别占总内表面积的1.56%和1.59%,均小于5%,满足全淹没灭火方式的条件。
- Abstract:
- After technical and economic comparison of five kinds of common automatic fire extinguishing systems, ultrafine dry powder automatic fire extinguishing system was adopted in the fire protection system design of an urban utility tunnel project in Changsha. The fire extinguishing design was calculated by volumetric method, and the fire extinguishing concentration, filling capacity of each device and spacing of fire extinguishing devices in power cabin and integrated cabin were determined, which were 0.15 kg/m3, 5 kg, 3.3 m and 3.2 m, respectively. After inspection, percentages of the open area in total internal surface area of the automatic fire protection system in the power cabin and integrated cabin were 1.56% and 1.59%, respectively, both less than 5%, which met the conditions of the total submergence fire extinguishing mode.
相似文献/References:
[1]曹益宁,董永红.城市综合管廊入廊污水管道及重要节点的设计[J].中国给水排水,2018,34(20):67.
CAO Yi ning,DONG Yong hong.Design of Sewage Pipe and Important Nodes of Urban Utility Tunnel[J].China Water & Wastewater,2018,34(14):67.
[2]寇殿良,袁建平,陈雪梅.高压细水雾灭火系统在综合管廊中的应用[J].中国给水排水,2018,34(20):72.
KOU Dian liang,YUAN Jian ping,CHEN Xue mei.Application of High-pressure Water Mist Fire Extinguishing System in Utility Tunnel[J].China Water & Wastewater,2018,34(14):72.
[3]强健.综合管廊的功能区间及应用[J].中国给水排水,2020,36(18):45.
QIANG Jian.Functional Section in the Utility Tunnel and Its Application[J].China Water & Wastewater,2020,36(14):45.
[4]张晏晏,曹伟新,陆继诚,等.综合管廊超细干粉自动灭火系统设计探讨[J].中国给水排水,2020,36(22):136.
ZHANG Yan-yan,CAO Wei-xin,LU Ji-cheng,et al.Discussion on Design of Ultra-fine Dry Powder Automatic Fire Extinguishing System in Utility Tunnel[J].China Water & Wastewater,2020,36(14):136.
[5]唐兰,张月,王长祥.保障全周期本质安全的综合管廊规划编制方法及要求[J].中国给水排水,2020,36(24):60.
TANG Lan,ZHANG Yue,WANG Chang-xiang.Planning Compilation Methods and Technical Requirements for Utility Tunnel to Ensure Intrinsic Safety throughout the Life Cycle[J].China Water & Wastewater,2020,36(14):60.
[6]赫明水,王长祥,吕杨,等.城市综合管廊真空排水系统模型试验及设计技术研究[J].中国给水排水,2020,36(24):66.
HE Ming-shui,WANG Chang-xiang,L?Yang,et al.Research on Model Test and Design Technology about the Vacuum Drainage System of Utility Tunnel[J].China Water & Wastewater,2020,36(14):66.
[7]尚琳,刘远,何发龙,等.考虑人员安全疏散的综合管廊防火分区设计长度研究[J].中国给水排水,2020,36(24):72.
SHANG Lin,LIU Yuan,HE Fa-long,et al.Study on the Utility Tunnel Fire Compartment Design Length Considering Safe Evacuation[J].China Water & Wastewater,2020,36(14):72.
[8]刘志寅,薛逸明.南京君悦酒店给排水系统设计探讨[J].中国给水排水,2021,37(6):61.
LIU Zhi-yin,XUE Yi-ming.Discussion on Water Supply and Drainage System Design of Grand Hyatt Hotel in Nanjing[J].China Water & Wastewater,2021,37(14):61.
[9]许云骅,金善朝,徐浩煜.综合管廊运维目标、原则及新技术应用[J].中国给水排水,2021,37(8):53.
XU Yun-hua,JIN Shan-chao,XU Hao-yu.Targets, Principles and New Technologies Application of the Utility Tunnel Operation and Maintenance[J].China Water & Wastewater,2021,37(14):53.
[10]邓娟,郑爽.排水管道水力冲洗设施在综合管廊中的应用[J].中国给水排水,2021,37(8):101.
DENG Juan,ZHENG Shuang.Application of Drainage Pipe Hydraulic Flushing Facility in the Utility Tunnel[J].China Water & Wastewater,2021,37(14):101.