[1]冯桂学,陈燕,孙韶华,等.Fenton氧化法降解水中致嗅物质2,3,6-三氯苯甲醚[J].中国给水排水,2022,38(13):78-82.
FENGGui-xue,CHENYan,SUNShao-hua,et al.Fenton Oxidation for Degradation of Odorous Compound 2, 3, 6- trichloroanisole in Water[J].China Water & Wastewater,2022,38(13):78-82.
点击复制
FENGGui-xue,CHENYan,SUNShao-hua,et al.Fenton Oxidation for Degradation of Odorous Compound 2, 3, 6- trichloroanisole in Water[J].China Water & Wastewater,2022,38(13):78-82.
Fenton氧化法降解水中致嗅物质2,3,6-三氯苯甲醚
中国给水排水[ISSN:1000-4062/CN:12-1073/TU]
卷:
第38卷
期数:
2022年第13期
页码:
78-82
栏目:
出版日期:
2022-07-01
- Title:
- Fenton Oxidation for Degradation of Odorous Compound 2, 3, 6- trichloroanisole in Water
- Keywords:
- Fenton oxidation; odorous compound; 2; 3; 6-trichloroanisole; influencing factor; reaction kinetics
- 摘要:
- 采用Fenton高级氧化法降解致嗅物质2,3,6-三氯苯甲醚(2,3,6-TCA),考察其降解效果及动力学,探讨了溶液pH、Fe2+与H2O2物质的量之比、Fe2+浓度和反应时间对Fenton氧化法降解2,3,6-TCA的影响,并确定了最佳反应条件。结果表明,在溶液pH为3.0、Fe2+与H2O2物质的量之比为1∶136、Fe2+浓度为16 mg/L、反应时间为10 min条件下,Fenton氧化法可有效降解水中2,3,6-TCA,降解率可以达到91.6%。Fenton氧化法降解水中2,3,6-TCA的过程符合准一级动力学,且其反应速率常数随2,3,6-TCA初始浓度的升高而降低。水中2,3,6-TCA在Fenton氧化作用下主要发生脱氯反应,生成二氯苯酚。可见,Fenton高级氧化法可以有效应对水中致嗅物质2,3,6-三氯苯甲醚污染问题。
- Abstract:
- The performance and kinetics of Fenton advanced oxidation process for odorous compound 2, 3, 6-trichloroanisole degradation in water were investigated, the effects of solution pH, molar ratio of Fe2+ and H2O2, Fe2+ concentration and reaction time on the degradation of 2, 3, 6-trichloroanisole were discussed, and the optimum conditions for the degradation of 2, 3, 6-trichloroanisole were determined. When the reaction conditions were as follows: solution pH of 3.0, molar ratio of Fe2+ and H2O2 of 1∶136, Fe2+ concentration of 16 mg/L and the reaction time of 10 min, Fenton oxidation effectively degraded 2, 3, 6-trichloroanisole in water with an removal efficiency of 91.6%. The degradation of 2, 3, 6-trichloroanisole by Fenton advanced oxidation process conformed to quasi-first-order kinetics, and the reaction rate constant decreased with the increase of the initial concentration of 2, 3, 6-trichloroanisole. Fenton oxidation for the degradation of 2, 3, 6-trichloroanisole was dominated by dechlorination, and the intermediate product was dichlorophenol. Therefore, Fenton advanced oxidation is an effective process to deal with the pollution of 2, 3, 6-trichloroanisole in water.
更新日期/Last Update:
2022-07-01