[1]马凯,贾霞珍,赵林,等.氯胺消毒饮用水中消毒剂分解途径与预测模型构建[J].中国给水排水,2023,39(21):34-39.
MAKai,JIAXia-zhen,ZHAOLin,et al.Decomposition Pathway and Prediction Model Construction of Disinfectant in Chloramine Disinfection of Drinking Water[J].China Water & Wastewater,2023,39(21):34-39.
点击复制
MAKai,JIAXia-zhen,ZHAOLin,et al.Decomposition Pathway and Prediction Model Construction of Disinfectant in Chloramine Disinfection of Drinking Water[J].China Water & Wastewater,2023,39(21):34-39.
氯胺消毒饮用水中消毒剂分解途径与预测模型构建
中国给水排水[ISSN:1000-4062/CN:12-1073/TU]
卷:
第39卷
期数:
2023年第21期
页码:
34-39
栏目:
出版日期:
2023-11-01
- Title:
- Decomposition Pathway and Prediction Model Construction of Disinfectant in Chloramine Disinfection of Drinking Water
- Keywords:
- water quality prediction model; residual chlorine decay; total chlorine decay model; reaction kinetics
- 摘要:
- 采用水质模型预测管网水余氯值是管网水质管控的重要手段之一。基于前期开发的总氯胺衰减模型(TCDM),耦合自由氯分解反应模块开发得到了优化的总氯胺衰减模型(RTCDM)。同时,分别以南水北调原水、水厂出厂水、管网水为实验用水,研究不同条件下主体水的余氯衰减过程。对相同初始条件下RTCDM模型的预测结果与实验结果进行比较,发现RTCDM模型能够高精度再现实验测定值,各组实验的平均相对误差为0.2%~9%,该模型同时具有良好的实验条件敏感性。因此,对于氯胺消毒给水系统,不宜单纯考虑氯胺的分解过程,还应将水中存在的自由氯分解过程纳入衰减反应体系中,从而提高模型应用能力。
- Abstract:
- The application of water quality model in prediction of residual chlorine of pipe network is one of the important means for water quality control. Based on the previously developed total chlorine decay model (TCDM), a refined total chlorine decay model (RTCDM) was developed by coupling the free chlorine decomposition reaction module. In addition, the residual chlorine decay process of raw water from South-to-North Water Diversion Project, effluent from water treatment plant and pipe network water were investigated under different experimental conditions. The prediction results of RTCDM were compared with the experimental results under the same initial conditions, which indicated that the RTCDM was capable of predicting the experimental results with high accuracy. The mean relative error of each experiment was in the range of 0.2%-9%, and the model had good sensitivity to experimental conditions. Consequently, for chloramine disinfection water supply system, it is not appropriate to consider the decomposition process of chloramine alone, and the free chlorine decomposition process existing in water should be included in the chloramine decay reactions, so as to improve the adaptive capacity of the model.
相似文献/References:
[1]张心悦,周克梅,刘煜,等.供水管材对管壁生物膜特性和水质稳定性的影响[J].中国给水排水,2022,38(9):44.
ZHANG Xin-yue,ZHOU Ke-mei,LIU Yu,et al.Effect of Water Supply Pipe Material on Biofilm Characteristics and Water Quality Stability[J].China Water & Wastewater,2022,38(21):44.
[2]谢文熙,于川,李超,等.自由氯维护消毒措施抑制管道耗氯作用效果研究[J].中国给水排水,2023,39(19):41.
XIEWen-xi,YUChuan,LIChao,et al.Effect of Free Chlorine Maintenance Disinfection on Controlling Pipeline? induced Chlorine Consumption[J].China Water & Wastewater,2023,39(21):41.
更新日期/Last Update:
2023-11-01