WEIHai-juan.Design of a Large Underground Wastewater Treatment Plant and Its Operation Performance Analysis[J].China Water & Wastewater,2024,40(8):60-65.
大型地下式污水处理厂工艺设计与运行效果分析
- Title:
- Design of a Large Underground Wastewater Treatment Plant and Its Operation Performance Analysis
- 摘要:
- 上海白龙港污水处理厂新增一座规模为50×104 m3/d的地下式污水处理设施,设计采用预处理+AAO+高效沉淀池+滤布滤池工艺,设计出水水质执行《城镇污水处理厂污染物排放标准》(GB 18918—2002)一级A标准。2021年的实际运行数据表明,设计工艺对进水污染物的季节性波动呈现出较好的承受能力,各项污染物指标去除率均高于设计值,出水水质稳定,均优于一级A标准。基于物质流分析对主要处理单元的污染物去除能力进行评估,结果表明,预处理和生物处理阶段对污染物的去除率均能达到设计值。
- Abstract:
- A new underground wastewater treatment facility with a designed capacity of 50×104 m3/d was built in Bailonggang wastewater treatment plant in Shanghai. The process consists of pretreatment, AAO, high-efficiency sedimentation tank and cloth media filter, and the effluent quality is required to meet the first level A limit specified in Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918-2002). The actual operation data in 2021 showed that the process demonstrated a good ability to withstand the seasonal fluctuations of influent pollutants, the removal rate of each pollutant was higher than the design value, and the effluent quality was always better than the first level A limit specified in the discharge standard. The assessment results of pollutant removal capacity of the main treatment units based on mass flow analysis showed that the removal rates of pollutants in pretreatment and biological treatment stage all reached the design values.
相似文献/References:
[1]郝晓地,于文波,王向阳,等.地下式污水处理厂全生命周期综合效益评价[J].中国给水排水,2021,37(7):1.
HAO Xiao-di,YU Wen-bo,WANG Xiang-yang,et al.Life Cycle Comprehensive Efficiency Assessment on Underground Wastewater Treatment Plant[J].China Water & Wastewater,2021,37(8):1.
[2]颜廷文,邳竞尧,刘世德.大型地下式污水处理厂中臭氧处理工艺的设计[J].中国给水排水,2021,37(10):89.
YAN Ting-wen,PI Jing-yao,LIU Shi-de.Design of Ozonation Process in Large Underground Sewage Treatment Plant[J].China Water & Wastewater,2021,37(8):89.
[3]陈秀成.地下式污水处理厂用地指标分析及节地设计方向[J].中国给水排水,2023,39(4):53.
CHENXiu-cheng.Analysis of Land Quota and Land Conservation Design Direction of Underground Wastewater Treatment Plant[J].China Water & Wastewater,2023,39(8):53.
[4]董磊,张欣,杨一烽.《城镇地下式污水处理厂技术规程》要点简析[J].中国给水排水,2023,39(16):14.
DONGLei,ZHANGXin,YANGYi-feng.Synopsis of Key Points for Technical Specification for Urban Underground Wastewater Treatment Plant[J].China Water & Wastewater,2023,39(8):14.
[5]仲崇军,代世宇,王曼,等.地下式污水处理厂“双降一增”设计案例[J].中国给水排水,2024,40(4):59.
ZHONGChong-jun,DAIShi-yu,WANGMan,et al.Double Reduction and One Increase” of Underground Sewage Treatment Plant: A Design Case[J].China Water & Wastewater,2024,40(8):59.
[6]杨涛,何帅,崔容,等.地下式污水处理厂的卫生防护距离及臭气污染控制[J].中国给水排水,2024,40(6):67.
YANGTao,HEShuai,CUIRong,et al.Health Protection Zone and Odor Pollution Control of the Underground Wastewater Treatment Plant[J].China Water & Wastewater,2024,40(8):67.
[7]韩佩君,余军,胡新立,等.AAO+MBR工艺在高标准污水厂节地设计中的应用[J].中国给水排水,2024,40(16):65.
HANPei-jun,YUJun,HUXin-li,et al.Utilization of AAO+MBR Process for Land Saving Design of a Wastewater Treatment Plant with High Discharge Standard[J].China Water & Wastewater,2024,40(8):65.