- 摘要:
- 现行《城市综合管廊工程技术规范》(GB 50838—2015)中关于综合管廊防火分区设计长度的规定,虽然保证了综合管廊消防安全性,但是限制了综合管廊施工安装及运行维护效率。实践经验表明,防火分区设计长度具有一定的拓延空间。从人员安全疏散角度,提出综合管廊疏散安全性准则,构建基于改进社会力模型综合管廊人员安全疏散仿真模型,分析火灾环境参数(如能见度和烟气刺激性等)对人员安全疏散时间的影响,总结出防火分区设计长度与疏散时间之间的关系。研究结果表明,在充分考虑烟气刺激性的影响下,防火分区设计长度值可拓展至437 m。
- Abstract:
- In the existing standard Technical Code for Urban Utility Tunnel Engineering (GB 50838-2015), the provisions on the design length of the utility tunnel fire compartment, although guarantee the utility tunnel fire safety, they restrict the construction, installation, operation and maintenance efficiency of the utility tunnel. Practical experience indicates that the fire compartment design length has a certain extension space. From the perspective of personnel safe evacuation, this paper puts forward utility tunnel evacuation safety standards, and builds a utility tunnel personnel safe evacuation simulation model based on the improved social force model, analyzes environmental parameters of fire, such as visibility and flue gas excitant, influence on the safe evacuation time, and summarizes the relationship between the fire compartment design length and the evacuation time. The results show that the fire compartment design length can be extended to 437 m under the influence of smoke irritation.
相似文献/References:
[1]曹益宁,董永红.城市综合管廊入廊污水管道及重要节点的设计[J].中国给水排水,2018,34(20):67.
CAO Yi ning,DONG Yong hong.Design of Sewage Pipe and Important Nodes of Urban Utility Tunnel[J].China Water & Wastewater,2018,34(24):67.
[2]寇殿良,袁建平,陈雪梅.高压细水雾灭火系统在综合管廊中的应用[J].中国给水排水,2018,34(20):72.
KOU Dian liang,YUAN Jian ping,CHEN Xue mei.Application of High-pressure Water Mist Fire Extinguishing System in Utility Tunnel[J].China Water & Wastewater,2018,34(24):72.
[3]强健.综合管廊的功能区间及应用[J].中国给水排水,2020,36(18):45.
QIANG Jian.Functional Section in the Utility Tunnel and Its Application[J].China Water & Wastewater,2020,36(24):45.
[4]张晏晏,曹伟新,陆继诚,等.综合管廊超细干粉自动灭火系统设计探讨[J].中国给水排水,2020,36(22):136.
ZHANG Yan-yan,CAO Wei-xin,LU Ji-cheng,et al.Discussion on Design of Ultra-fine Dry Powder Automatic Fire Extinguishing System in Utility Tunnel[J].China Water & Wastewater,2020,36(24):136.
[5]唐兰,张月,王长祥.保障全周期本质安全的综合管廊规划编制方法及要求[J].中国给水排水,2020,36(24):60.
TANG Lan,ZHANG Yue,WANG Chang-xiang.Planning Compilation Methods and Technical Requirements for Utility Tunnel to Ensure Intrinsic Safety throughout the Life Cycle[J].China Water & Wastewater,2020,36(24):60.
[6]赫明水,王长祥,吕杨,等.城市综合管廊真空排水系统模型试验及设计技术研究[J].中国给水排水,2020,36(24):66.
HE Ming-shui,WANG Chang-xiang,L?Yang,et al.Research on Model Test and Design Technology about the Vacuum Drainage System of Utility Tunnel[J].China Water & Wastewater,2020,36(24):66.
[7]许云骅,金善朝,徐浩煜.综合管廊运维目标、原则及新技术应用[J].中国给水排水,2021,37(8):53.
XU Yun-hua,JIN Shan-chao,XU Hao-yu.Targets, Principles and New Technologies Application of the Utility Tunnel Operation and Maintenance[J].China Water & Wastewater,2021,37(24):53.
[8]邓娟,郑爽.排水管道水力冲洗设施在综合管廊中的应用[J].中国给水排水,2021,37(8):101.
DENG Juan,ZHENG Shuang.Application of Drainage Pipe Hydraulic Flushing Facility in the Utility Tunnel[J].China Water & Wastewater,2021,37(24):101.
[9]赵忠梁.渠县黄花大道综合管廊通风设计[J].中国给水排水,2021,37(10):79.
ZHAO Zhong-liang.Design for Ventilation of Huanghua Avenue Utility Tunnel in Qu County[J].China Water & Wastewater,2021,37(24):79.
[10]刘琳,刘勇,王树人.砂砾地层矩形截面管廊顶管施工超挖空洞消除方法[J].中国给水排水,2021,37(10):154.
LIU Lin,LIU Yong,WANG Shu-ren.An Eliminating Method of Over-excavated Holes in Pipe-jacking Construction of Utility Tunnel with Rectangular Cross-section in Gravel Stratum[J].China Water & Wastewater,2021,37(24):154.