WANG Xiao-yun,FU Ai-min,LEE King-ming.Combined Process of Aeration Pond and Constructed Wetland for Treatment of Rural Sewage[J].China Water & Wastewater,2021,37(21):64-68.
曝气氧化塘+人工湿地组合工艺处理农村污水
- Title:
- Combined Process of Aeration Pond and Constructed Wetland for Treatment of Rural Sewage
- Keywords:
- rural sewage; aeration pond; constructed wetland; surface loading
- 摘要:
- 以台湾省台东县关山人工湿地系统为研究对象,探讨了曝气氧化塘+人工湿地组合工艺处理农村污水的效果。2008年8月—2018年12月,每月采集1次数据,共收集125组数据。结果表明,人工湿地系统对BOD5的平均去除率为(61.55±16.71)%,平均表面污染物负荷为(1.23±0.52) g/(m2·d);对SS的平均去除率为(63.39±11.18)%,平均表面污染物负荷为(2.62±2.36) g/(m2·d);对NH4+-N的平均去除率为(82.21±12.11)%,平均表面污染物负荷为(1.98±0.34) g/(m2·d);对TN的平均去除率为(67.88±13.89)%,平均表面污染物负荷为(1.78±1.01) g/(m2·d);对TP的平均去除率为(71.31±12.31)%,平均表面污染物负荷为(0.13±0.05) g/(m2·d)。该工艺运行稳定,处理效果好,出水水质满足台湾省相关水质标准要求。整个系统结合生态景观,构建亲水环境,表现出良好的环境效益。
- Abstract:
- The effect of a combined process of aeration pond and constructed wetland on the treatment of rural sewage was explored in Guanshan Constructed Wetland, Taidong County, Taiwan Province. From August 2008 to December 2018, a total of 125 groups of data were collected through the data collection for once a month. The removal efficiencies of BOD5, SS, NH4+-N, TN and TP by the constructed wetland system were (61.55±16.71)%, (63.39±11.18)%, (82.21±12.11)%, (67.88±13.89)% and (71.31±12.31)%, respectively, and the average surface pollutant loading rates of BOD5,SS,NH4+-N,TN and TP were (1.23±0.52) g/(m2·d), (2.62±2.36) g/(m2·d), (1.98±0.34) g/(m2·d), (1.78±1.01) g/(m2·d) and (0.13±0.05) g/(m2·d), respectively. The process operated stably with a good treatment performance, and the effluent quality met the requirements of relevant water quality standards of Taiwan Province. The whole system was combined with the ecological landscape to build a hydrophilic environment, and showed good environmental benefits.
相似文献/References:
[1]董倩倩,李骏飞,初振宇.垂直-水平流人工湿地处理农村污水效果及影响因素[J].中国给水排水,2022,38(21):101.
DONGQian-qian,LIJun-fei,CHUZhen-yu.Treatment Effect of Vertical-horizontal Flow Constructed Wetland System on Rural Wastewater and Its Influencing Factors[J].China Water & Wastewater,2022,38(21):101.
[2]刘天顺,张国威,刘志生.负压排水系统在农村污水收集中的应用[J].中国给水排水,2022,38(24):64.
LIUTian-shun,ZHANGGuo-wei,LIUZhi-sheng.Application of Negative Pressure Drainage System in Rural Sewage Collection[J].China Water & Wastewater,2022,38(21):64.
[3]潘增锐,芮旭东,邓震,等.杭州市《“农村污水零直排村”创建技术导则》简析[J].中国给水排水,2023,39(2):21.
PANZeng-rui,RUIXu-dong,DENGZhen,et al.Discussion on the Technical Guideline for “Rural Sewage Zero Direct Discharge Village” Construction in Hangzhou City[J].China Water & Wastewater,2023,39(21):21.
[4]方施施,张立明,成进棋.宜兴市低洼圩区、丘陵地区农村生活污水管网设计[J].中国给水排水,2023,39(8):83.
FANGShi-shi,ZHANGLi-ming,CHENGJin-qi.Design of Rural Domestic Sewage Network in Low-lying Polder and Hilly Areas of Yixing City[J].China Water & Wastewater,2023,39(21):83.
[5]刘建伟,迟名佳,田洪钰,等.农村污水多反应区生物-生态组合工艺设计及应用[J].中国给水排水,2023,39(14):75.
LIUJian-wei,CHI Ming-jia,TIANHong-yu,et al.Design and Application of a Biological-Ecological Combined Process with Multiple Reaction Zones for Rural Wastewater Treatment[J].China Water & Wastewater,2023,39(21):75.
[6]韦怀德,李发站,谷超.一体化多级AO生物膜反应器处理农村污水研究[J].中国给水排水,2023,39(17):81.
WEIHuai-de,LIFa-zhan,GUChao.Integrated Multistage AO Biofilm Reactor for Treatment of Rural Sewage[J].China Water & Wastewater,2023,39(21):81.
[7]杨亮,马军,陈志强.我国农村污水处理现状综述[J].中国给水排水,2024,40(10):28.
YANGLiang,MAJun,CHENZhi-qiang.Current Situation of Rural Sewage Treatment in China:A Review[J].China Water & Wastewater,2024,40(21):28.