- 摘要:
- 建立了离子色谱法同时测定瓶(桶)装饮用水中溴酸盐、氯酸盐和高氯酸盐的方法。选用Ionpac AS20阴离子分析柱,在线产生5~55 mmol/L KOH淋洗液,流速1.00 mL/min,柱温30 ℃,抑制器电流137 mA,进样体积500 μL,电导检测器检测。应用该方法检测50份市售瓶(桶)装饮用水,结果表明,溴酸盐、氯酸盐和高氯酸盐在0.005~0.500 mg/L范围内线性良好,相关系数均大于0.999 0,测定结果精密度高(RSD<1.0%);溴酸盐、氯酸盐和高氯酸盐的方法检出限分别为1.5、1.0、1.5 μg/L;定量限分别为5.0、3.3、5.0 μg/L;回收率分别为87.0 %~101.5%、93.4 %~118.0%和90.9%~114.0%。50份瓶(桶)装饮用水中,溴酸盐、氯酸盐和高氯酸盐检出率分别为40.0%、66.0%、14.0%,均未超标。该方法快速、灵敏、准确,适用于瓶(桶)装饮用水中溴酸盐、氯酸盐和高氯酸盐的同时检测。
- Abstract:
- This paper established a method of ion chromatography for simultaneous determination of bromate, chlorate and perchlorate in bottled water. The anion column was Ionpac AS20. 5-55 mmol/L KOH eluent was generated online, the flow rate was 1.00 mL/min, the column temperature was 30 ℃, the electric current of suppressor was 137 mA, and the sample volume was 500 μL. The sample was detected by a conductivity detector. The method was applied to detect 50 commercial bottles of drinking water. This method had good linear relation for bromate, chlorate and perchlorate in the range of 0.005-0.500 mg/L. The correlation coefficients were all greater than 0.999 0, and the precision was high (RSD<1.0%). The detection limits of bromate, chlorate and perchlorate were 1.5 μg/L, 1.0 μg/L and 1.5 μg/L, respectively, the quantitative limits were 5.0 μg/L, 3.3 μg/L and 5.0 μg/L, respectively, and the recovery rate were 87.0%-101.5%, 93.4%-118.0% and 90.9%-114.0%, respectively. The detection rates of bromate, chlorate and perchlorate in 50 bottles of drinking water were 40.0%, 66.0% and 14.0%, respectively, none of which exceeded the standard. This method is rapid, simple, sensitive and is suitable for simultaneous detection of bromate, chlorate and perchlorate in bottled water.
相似文献/References:
[1]杨璟爱,关玉春,赵莉,等.碳酸钠-碳酸氢钠体系离子色谱法测定水中丙烯酸[J].中国给水排水,2021,37(16):130.
YANG Jing-ai,GUAN Yu-chun,ZHAO Li,et al.Determination of Acrylic Acid in Water by Sodium Carbonate-Sodium Bicarbonate System Ion Chromatography[J].China Water & Wastewater,2021,37(6):130.
[2]王赫,彭锦玉,王全勇,等.臭氧/生物活性炭流化床预处理对净水效率的影响[J].中国给水排水,2023,39(5):46.
WANGHe,PENGJin-yu,WANGQuan-yong,et al.Effect of Ozone/Biological Activated Carbon Fluidized Bed Pretreatment on Water Purification Efficiency[J].China Water & Wastewater,2023,39(6):46.
[3]项念念,黄朝颜,刘煦,等.离子色谱法同时测定工业级乙酸钠和柠檬酸[J].中国给水排水,2023,39(22):150.
XIANGNian-nian,HUANGZhao-yan,LIUXu,et al.Ion Chromatography for Simultaneous Determination of Industrial Grade Sodium Acetate and Citric Acid[J].China Water & Wastewater,2023,39(6):150.
[4]左绘雯,金鑫,金鹏康.臭氧混凝耦合工艺的溴酸盐消毒副产物生成特性[J].中国给水排水,2024,40(21):73.
ZUOHui-wen,JINXin,JINPeng-kang.Formation Characteristics of Bromate Disinfection By-product in Hybrid Ozonation-Coagulation Process[J].China Water & Wastewater,2024,40(6):73.