GUANYong-nian.Biological Aerated Filter, High Efficiency Sedimentation Tank and V-type Filter for Upgrading and Reconstruction of a High Discharge Standard Wastewater Treatment Plant[J].China Water & Wastewater,2023,39(14):66-70.
BAF+ 高效沉淀池+V型滤池用于污水厂高标准提标改造
- Title:
- Biological Aerated Filter, High Efficiency Sedimentation Tank and V-type Filter for Upgrading and Reconstruction of a High Discharge Standard Wastewater Treatment Plant
- 摘要:
- 苏州工业园区某污水处理厂处理规模为20×104 m3/d,设计采用改良型AAO+滤布滤池+紫外线消毒处理工艺,出水水质执行《城镇污水处理厂污染物排放标准》(GB 18918—2002)一级A标准。为达到苏州市政府提出的出水水质提升至地表水准Ⅳ类标准的要求,在提标改造工程中采用了BAF(DN型+CN型)+高效沉淀池+V型滤池+紫外线与次氯酸钠联合消毒的深度处理工艺,以强化对COD、NH3-N、TN、TP和SS的去除,同时保障尾水的消毒效果。实际运行表明,工程运行状况良好,出水水质能够稳定达标
- Abstract:
- The treatment scale of a wastewater treatment plant in Suzhou industrial park is 20×104 m3/d. The process consists of modified AAO, textile filter and UV disinfection process, and the effluent quality is required to meet the first level A limit specified in the Discharge Standard of Pollutants for Municipal Wastewater Treatment Plant (GB 18918-2002). To meet the requirements of upgrading the effluent quality to surface water quasi class Ⅳ standard proposed by Suzhou government, the advanced treatment process of biological aerated filter (DN type and CN type), high efficiency sedimentation tank, V-type filter and UV combined with sodium hypochlorite disinfection is adopted in the upgrading project to enhance the removal of COD, NH3-N, TN, TP and SS and ensure the disinfection performance of tail water. The actual operation shows that the project is in good condition and the effluent quality stably meets the discharge standard.
相似文献/References:
[1]熊建英.MBBR+磁混凝工艺用于污水处理厂提标改造[J].中国给水排水,2018,34(20):50.
XIONG Jian ying.Application of MBBR + Magnetic Coagulation Process for Upgrading of Wastewater Treatment Plant[J].China Water & Wastewater,2018,34(14):50.
[2]卢如,巨志剑,杜琼.采用A/O工艺的污水处理厂提标改造工程设计[J].中国给水排水,2018,34(20):56.
LU Ru,JU Zhi jian,DU Qiong.Upgrading and Reconstruction Project Design of Wastewater Treatment Plant with A/O Process[J].China Water & Wastewater,2018,34(14):56.
[3]周亚梁,黄东月.南方某污水处理厂提标改造工艺运行优化[J].中国给水排水,2020,36(8):113.
[4]许晓明,刘宇心,闫萍,等.以工业废水为主的污水厂准Ⅳ类水质提标扩建工程设计[J].中国给水排水,2020,36(18):60.
XU Xiao-ming,LIU Yu xin,YAN Ping,et al.A Design Case of Upgrading and Expansion Project to Meet the Quasi-Ⅳ Class Standard in a WWTP with Industrial Wastewater as Its Major Influent[J].China Water & Wastewater,2020,36(14):60.
[5]聂健锋,曾超.三峡库区Carrousel氧化沟工艺提标升级改造设计[J].中国给水排水,2020,36(18):66.
NIE Jian-feng,ZENG Chao.Design of Upgrading and Reconstruction of Carrousel Oxidation Ditch Process in Three Gorges Reservoir Area[J].China Water & Wastewater,2020,36(14):66.
[6]张莉,余国富,瞿露,等.重庆市某污水处理厂一级A提标改造运行效果分析[J].中国给水排水,2020,36(18):95.
ZHANG Li,YU Guo-fu,QU Lu,et al.Analysis on the Operation Effect of a WWTP Upgrading Project for the Firstlevel A Standard in Chongqing[J].China Water & Wastewater,2020,36(14):95.
[7]马丽芳,陈菊香,孙锐.克拉玛依市某污水处理厂一级A提标改造工程实例[J].中国给水排水,2020,36(18):122.
MA Li-fang,CHEN Ju-xiang,SUN Rui.A WWTP Upgrading Reconstruction Project to Meet the First Level A Discharge Standard in Karamay[J].China Water & Wastewater,2020,36(14):122.
[8]孙高升,王东东,弋凡,等.淮河流域地表水类Ⅳ类标准污水深度处理工艺研究[J].中国给水排水,2020,36(19):16.
SUN Gao-sheng,WANG Dong-dong,YI Fan,et al.Advanced Wastewater Treatment Process with Effluent Quality Meeting Level Quasi Ⅳ Criteria of Surface Water in Huai River Basin[J].China Water & Wastewater,2020,36(14):16.
[9]李亮,邱宏俊.改良A2/O氧化沟强化生化处理技术用于污水厂提标改造[J].中国给水排水,2020,36(20):124.
LI Liang,QIU Hong-jun.Application of Improved A2/O Oxidation Ditch Enhanced Biochemical Treatment Process for Upgrading the Wastewater Treatment Plant[J].China Water & Wastewater,2020,36(14):124.
[10]黄志心.城镇污水处理厂提标改造实践与思考[J].中国给水排水,2020,36(22):48.
HUANG Zhi-xin.Practice and Thinking of Upgrading and Reconstruction of Municipal Wastewater Treatment Plant[J].China Water & Wastewater,2020,36(14):48.