WANGQian,WUXue-song,LIWei,et al.Optimized Operation Strategy for Energy Saving and Consumption Reduction of Sludge Dewatering Process in Qinghe Ⅱ Reclaimed Water Plant of Beijing Drainage Group[J].China Water & Wastewater,2024,40(2):94-98.
北排清河二厂污泥脱水工艺节能降耗优化运行策略
- Title:
- Optimized Operation Strategy for Energy Saving and Consumption Reduction of Sludge Dewatering Process in Qinghe Ⅱ Reclaimed Water Plant of Beijing Drainage Group
- Keywords:
- sludge treatment; sludge dewatering; energy saving and consumption reduction; thickener; pre-dehydrator; plate and frame filter press
- 摘要:
- 在“碳达峰、碳中和”的政策驱动下,为优化脱水工艺实现节能减排,2022年北排清河第二再生水厂污泥处理中心通过对浓缩机、预脱水机、板框压滤机三个生产区域的设备处理量、运行数量和台时进行调控,实现了脱水区域电单耗的显著降低。通过提升浓缩机的进泥负荷、减少设备开机频次,该区域电单耗下降17.52 kW·h/tDS;通过优化预脱水机开机频次和螺旋输送机运行,该区域电单耗下降3.48 kW·h/tDS;通过对板框区域采取分区运行、低压进泥泵低频率运行、无进料回流运行等措施,该区域电单耗同比下降约51.89 kW·h/tDS。采取以上工艺调控措施后,2022年脱水区域总电单耗为324.39 kW·h/tDS,较2021年下降17.9%,节电对应CO2减排量约1 440.09 t。
- Abstract:
- Driven by the policy of “carbon peak and carbon neutrality”, in order to optimize the energy saving and emission reduction of dewatering process, the sludge treatment center of Qinghe Ⅱ reclaimed water plant of Beijing Drainage Group realized significantly reduction of unit power consumption in the dewatering area in 2022 by regulating the equipment treatment capacity, equipment operation quantity and unit hours in the three production areas of thickener, pre-dehydrator and plate and frame filter press. By increasing the sludge load of thickener and reducing the frequency of equipment start-up, the unit power consumption in this area decreased by 17.52 kW·h/tDS. By optimizing the start-up frequency of the pre-dehydrator and the operation of the screw conveyor, the unit power consumption in this area decreased by 3.48 kW·h/tDS. The unit power consumption in the plate and frame area decreased by 51.89 kW·h/tDS year on year by taking measures such as zoning operation, low frequency operation of low pressure sludge pump and no feed reflux operation. Through the above process control measures, the total unit power consumption in the dewatering area have decreased to 324.39 kW·h/tDS in 2022, 17.9% lower than that in 2021, and the power saving corresponds to about 1 440.09 t of CO2 emission reduction.
相似文献/References:
[1]宋晓雅.小红门污泥热水解厌氧消化项目运行两周年之回顾[J].中国给水排水,2018,34(22):116.
SONG Xiao-ya.Review of Biennial Operation of Xiaohongmen Thermal Hydrolysis Anaerobic Digestion System[J].China Water & Wastewater,2018,34(2):116.
[2]仝恩从.保定市污泥处理中心项目的工艺选择及思考[J].中国给水排水,2018,34(20):21.
TONG En cong.Process Selection and Thought of Baoding Sludge Treatment Center Project[J].China Water & Wastewater,2018,34(2):21.
[3]林明,庄毅璇,李建,等.某污水处理厂污泥处理系统技术改造[J].中国给水排水,2018,34(20):109.
LIN Ming,ZHUANG Yi xuan,LI Jian,et al.Technological Transformation of Sludge Treatment System in a WWTP[J].China Water & Wastewater,2018,34(2):109.
[4]王首都,黄申斌,魏小玲,等.立式移动地板发酵仓技术在崇明某污水厂的应用[J].中国给水排水,2020,36(14):138.
WANG Shou-du,HUANG Shen-bin,WEI Xiao-ling,et al.Application of Vertical Mobile Floor Fermentation Bin in a Sewage Treatment Plant in Chongming District[J].China Water & Wastewater,2020,36(2):138.
[5]颜莹莹,孟春霖,梁远,等.连续深度脱水耦合低温干化工艺用于鹰潭污泥处理厂[J].中国给水排水,2020,36(16):105.
YAN Ying-ying,MENG Chun-lin,LIANG Yuan,et al.Continuous Deep Dewatering Coupled with Low Temperature Drying Process in Yingtan Sludge Treatment Plant[J].China Water & Wastewater,2020,36(2):105.
[6]孙建升,叶雅丽,郑兴灿,等.昆明市污水处理厂污泥处理工艺的研究与探讨[J].中国给水排水,2020,36(18):108.
SUN Jian-sheng,YE Ya-li,ZHENG Xing-can,et al.Research and Discussion on the Sludge Disposal Technology of Kunming WWTPs[J].China Water & Wastewater,2020,36(2):108.
[7]孙志涛,李军,王秀杰,等.吸附架桥机理主导下APAM的多级絮凝效能[J].中国给水排水,2022,38(1):31.
SUN Zhi-tao,LI Jun,WANG Xiu-jie,et al.Multi?stage Flocculation Efficiency of APAM Led by Adsorption and Bridging Mechanism[J].China Water & Wastewater,2022,38(2):31.
[8]孟继安,钟达文,孙昊,等.SEUE-WAO污泥湿式氧化工艺的生产性试验研究[J].中国给水排水,2023,39(15):1.
MENGJi-an,ZHONGDa-wen,SUNHao,et al.Full-scale Study on SEUE-WAO Sludge Wet Air Oxidation Process[J].China Water & Wastewater,2023,39(2):1.
[9]沈玉东,李秋,刘智皆,等.北江水源自来水厂行走式板框压滤机污泥脱水研究[J].中国给水排水,2024,40(15):55.
SHENYu-dong,LIQiu,LIUZhi-jie,et al.Application of Walking Plate and Frame Filter Press for Sludge Dewatering in Waterworks with Beijiang River Water Source[J].China Water & Wastewater,2024,40(2):55.