- 摘要:
-
重力流污水管道纳入综合管廊需要满足一定的外部条件及其特有的技术要求,尤其当道路平坦没有坡度可以利用时,设计难度加大。以珠海市呈祥路综合管廊为设计实例,重点介绍了入廊污水管道管材选择、检查井、通气口、接驳井等设计要点,并对综合管廊断面、平面、竖向、特殊节点设计进行了阐述,可为其他综合管廊纳入重力流污水管道的项目提供借鉴。
- Abstract:
-
It is necessary to meet certain external conditions and special technical requirements for the integration of gravity-flow sewage pipeline into the utility tunnel, especially when the road is flat without slope, the design is very difficult. Taking Zhuhai Chengxiang Road utility tunnel design as an example, the design key points of pipe selection, inspection well, air vent and connection well were emphasized. The cross section design, plan design, vertical design, special node design were expounded in this case. It could be used as reference for other projects that integrate gravityflow sewage pipeline into utility tunnel.
相似文献/References:
[1]孙永利,张维,郑兴灿,等.城镇居民人均日生活污水污染物产生量测算之产污规律[J].中国给水排水,2020,36(6):1.
[2]范荣桂,刘娜,尹利鹏,等.污泥厌氧催化快速发酵产VFAs的试验研究[J].中国给水排水,2020,36(11):69.
[3]镇祥华,余琴芳,万年红,等.污水处理厂二级出水深床滤池超深度脱氮研究[J].中国给水排水,2020,36(11):91.
[4]赵美玲,朱涛,冯江,等.水力模型在合流制调蓄池进水管改造中的应用[J].中国给水排水,2020,36(7):114.
[5]朱一文,王文亮.基于水文方法的暴雨调节塘规模计算[J].中国给水排水,2020,36(7):118.
[6]李骏飞,李欢,杨磊三.粤港澳大湾区创新治水模式分享[J].中国给水排水,2020,36(8):1.
[7]李激,王燕,熊红松,等.城镇污水处理厂消毒设施运行调研与优化策略[J].中国给水排水,2020,36(8):7.
[8]赵锡锋,李兴强,李军.好氧颗粒污泥技术中试研究及应用进展[J].中国给水排水,2020,36(8):30.
[9]王建西.PTA2O工艺用于养猪废水处理及其Anammox现象分析[J].中国给水排水,2020,36(8):56.
[10]高海英,邓磊,侯晓庆,等.MBR工艺在西安经开草滩污水处理厂中的应用[J].中国给水排水,2020,36(8):63.
[11]莫俊锋,王文亮,白献宇,等.基于设计暴雨法的CSO调蓄池池容计算方法探讨[J].中国给水排水,2020,36(8):77.
[12]郭健.纳入大直径热力管的综合管廊设计研究[J].中国给水排水,2020,36(8):82.
[13]蒙政成,冼萍,黄付平,等.NCMBR工艺在工业园区污水处理工程中的应用[J].中国给水排水,2020,36(8):88.