SHENYu-dong,LIQiu,LIUZhi-jie,et al.Application of Walking Plate and Frame Filter Press for Sludge Dewatering in Waterworks with Beijiang River Water Source[J].China Water & Wastewater,2024,40(15):55-60.
北江水源自来水厂行走式板框压滤机污泥脱水研究
- Title:
- Application of Walking Plate and Frame Filter Press for Sludge Dewatering in Waterworks with Beijiang River Water Source
- Keywords:
- waterworks; walking plate and frame filter press; sludge dewatering; Beijiang River water source
- 摘要:
- 通过分析北江水源自来水厂浓缩污泥的特性,探讨了行走式板框压滤机用于污泥脱水的效果。结果发现,使用阳离子、低离子度、粉剂型聚丙烯酰胺作为污泥调理药剂对板框压滤脱水效率具有显著的提升效果,同时针对进泥含固率为5%的浓缩污泥,当进料时间为10 min、进料压强为0.5 MPa、隔膜挤压压强为1.5 MPa时,建议挤压时间为35 min。
- Abstract:
- By examining the characteristics of thickened sludge from a waterworks with Beijiang River as the source water, the performance of walking plate and frame filter press on sludge dewatering was explored. The utilization of cationic, low-ionic, and powdered polyacrylamide as agents for sludge conditioning significantly enhanced the dewatering efficiency of the plate and frame filter press. Simultaneously, for concentrated sludge with a solid content of 5%, the recommended diaphragm squeezing time was 35 minutes when the feeding time was 10 minutes, the feeding pressure was 0.5 MPa, and the diaphragm squeezing pressure was 1.5 MPa.
相似文献/References:
[1]黄仲均,刘佳伟.基于一体化净水装置的自来水厂改造扩能案例分析[J].中国给水排水,2018,34(22):82.
HUANG Zhong-jun,LIU Jia-wei.Reconstruction and Expansion Design of Waterworks Based on Integrated Water Purification Device[J].China Water & Wastewater,2018,34(15):82.
[2]刘彦华,苏锡波,高迎亮,等.城镇自来水厂平流沉淀池改造技术与实践[J].中国给水排水,2020,36(14):131.
LIU Yan-hua,SU Xi-bo,GAO Ying-liang,et al.Renovation Technology and Practice of Horizontal Flow Sedimentation Tank in Urban Waterworks[J].China Water & Wastewater,2020,36(15):131.
[3]李丰庆.我国超大超滤水厂——广州北部水厂工艺设计[J].中国给水排水,2021,37(10):66.
LI Feng-qing.Process Design of the Super Large Ultrafiltration Waterworks in China: Guangzhou Beibu Waterworks[J].China Water & Wastewater,2021,37(15):66.
[4]赵新娟,刘伯一.短流程超滤膜工艺在凌庄水厂的应用[J].中国给水排水,2021,37(10):71.
ZHAO Xin-juan,LIU Bo-yi.Application of Short Process Ultrafiltration Membrane in Lingzhuang Waterworks[J].China Water & Wastewater,2021,37(15):71.
[5]黄孟斌,武洋,王梅芳,等.深圳长流陂水厂网格絮凝池提升改造应用实践[J].中国给水排水,2021,37(12):116.
HUANG Meng-bin,WU Yang,WANG Mei-fang,et al.Application Practice of Grid Flocculation Tank Upgrading and Reconstruction in Shenzhen Changliupi Waterworks[J].China Water & Wastewater,2021,37(15):116.
[6]何嘉莉,袁耀芬,周沛良,等.自来水厂混凝剂自动精准投加系统建设与运行[J].中国给水排水,2021,37(18):139.
HE Jia-li,YUAN Yao-fen,ZHOU Pei-liang,et al.Construction and Operation of Automatic and Accurate Coagulant Dosing System in Waterworks[J].China Water & Wastewater,2021,37(15):139.
[7]杨存满,鞠佳伟,袁芳,等.基于PSO-BP神经网络的水厂智能消毒预测模型[J].中国给水排水,2022,38(3):57.
YANGCun-man,JUJia-wei,YUAN Fang,et al.Research on Intelligent Disinfection Prediction Model of Waterworks Based on PSO-BP Neural Network[J].China Water & Wastewater,2022,38(15):57.
[8]陈仁杰,刘明辉,丁陈龙,等.基于水厂砂滤填料附着物的BAF启动及其硝化性能[J].中国给水排水,2022,38(8):25.
CHENRen-jie,LIUMing-hui,DINGChen-long,et al.Startup of Biological Aerated Filter Seeded with Attached Microbes from Sand Filter in a Waterworks and Its Nitrification Performance[J].China Water & Wastewater,2022,38(15):25.
[9]李颖强,麻庆广,刘则华,等.我国南方典型自来水厂中游离氨基酸浓度及去除特性[J].中国给水排水,2022,38(13):28.
LIYing-qiang,MAQing-guang,LIUZe-hua,et al.Concentration Level and Removal of Fifteen Free Amino Acids in Eight Drinking Water Treatment Plants in South China[J].China Water & Wastewater,2022,38(15):28.
[10]宋欣,李燕君,黄慧,等.臭氧-上向流BAC工艺对常规及新污染物的控制效果[J].中国给水排水,2024,40(3):1.
SONGXin,LIYan-jun,HUANGHui,et al.Control of Conventional and Emerging Contaminants by Ozone-Upflow Biological Activated Carbon Process[J].China Water & Wastewater,2024,40(15):1.